GEZE
HYGIENIC DOORS
![HYGIENIC DOORS - geze](https://static.wixstatic.com/media/090e92_6d4235e0a2f847a1aeb0b16f2f5ce325~mv2.jpg/v1/fill/w_405,h_305,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/StageProd_Des%20(1).jpg)
For 1-leaf door systems Yes
​
Leaf weight (max.) 1-leaf 200 kg
​
Opening width 1-leaf 800 mm 2500 mm
​
Temperature range -15 °C 50 °C
​
IP rating IP20
​
Disconnection from mains Main switch in the drive
​
Product tested in accordance with DIN 18650, EN 16005, DIN EN ISO 13849: Performance Level D
POWERDRIVE PL-HT
-
Consists of drive kit, aluminium profiles, floor guide profiles and seals
-
Door construction can be freely selected by the customer
-
Increased air impermeability by lowering and pressing the door leaf against the frame structure
-
All round seal reduces the air permeability of the closed sliding door system
-
Optimised opening widths for hospital operation (nurse opening, cleaning opening, bed opening)
-
Can be networked via CAN bus and integrated into building technology management systems
-
Independent error recognition and recording
-
Freely configurable inputs and outputs for different functions
-
Integrated rechargeable battery for emergency opening and closing in the event of a power failure
-
Self-cleaning roller carriage reduces maintenance effort and costs
-
Various mechanical and electrical lockings are optionally available
AUTOMATIC LINEAR SLIDING DOOR SYSTEM FOR LARGE, HEAVY DOORS IN AREAS WITH INCREASED HYGIENE REQUIREMENTS
Application Areas
-
Single leaf sliding door systems
-
Interior and exterior doors with increased hygiene demands like in laboratories, clean rooms, lobbies
-
Opening widths from 800 to 2500 mm possible
-
Door leaf weights of up to 200 kg
-
Fine-framed profile system with ISO glass is the suitable profile system
ECDRIVE H
-
Consists of a drive kit and aluminium profiles
-
Offers numerous options for project-specific collaboration with installation companies
-
Special track reduces dirt residue and simplifies hygienic cleaning
-
Optimised opening widths for hospital operation (nurse opening, cleaning opening, bed opening)
-
Can be networked via CAN bus and integrated into building technology management systems
-
Independent error recognition and recording
-
Freely configurable inputs and outputs for different functions
-
Integrated rechargeable battery for emergency opening and closing in the event of a power failure
-
Self-cleaning roller carriage reduces maintenance effort and costs
-
Various mechanical and electrical lockings are optionally available
![HYGIENIC DOORS - geze](https://static.wixstatic.com/media/090e92_81991028271e455c92e92bfd756d2c98~mv2.jpg/v1/fill/w_300,h_225,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/ecdrive-h.jpg)
AUTOMATIC LINEAR SLIDING DOOR SYSTEM FOR AREAS WITH INCREASED HYGIENE REQUIREMENTS
Application Areas
-
Single and double leaf sliding door systems
-
Interior and exterior doors with increased hygiene demands like in laboratories, clean rooms, lobbies
-
Opening widths from 700 to 2200 mm possible
-
Door leaf weight of up to 120 kg per leaf
-
Fine-framed profile system with ISO glass is the suitable profile system
For 1-leaf door systems Yes
​
For 2-leaf door systems Yes
​
Leaf weight (max.) 1-leaf 120 kg
​
Leaf weight (max.) 2-leaf 120 kg
​
Opening width 1-leaf 700 mm 2200 mm
​
Opening width 2-leaf 900 mm 2200 mm
​
Temperature range -15 °C 50 °C
​
IP rating IP20
​
Disconnection from mains Main switch in the drive
​
Product tested in accordance with DIN 18650, EN 16005, DIN EN ISO 13849: Performance Level D, AutSchR